FFU flow sensor – non-contact flow measurement

The non-contact FFU ultrasonic flowmeter detects the flow volume of conductive and non-conductive liquids. Swimming against the current requires more strength than with the current – this is the simple fact on which ultrasonic flow measurement according to the phase difference process is based. Its compact design enables the device to be used in a wide range of applications, including those with limited space. This sensor with an enclosure rating of IP67 features a seal-free sensor design with high-quality polysulfone (Ultrason S), which not only makes it possible to use the device in harsh ambient conditions, but also ensures high process reliability. The large cleartext display also helps provide simple, fast, and hassle-free commissioning.

Features

  • Flow sensor for conductive and non-conductive liquids
  • Compact design with no moving parts
  • Process temperature up to 80 °C, process pressure up to 16 bar
  • High chemical resistance due to seal-free sensor design
  • Large display with membrane keyboard
  • Integrated empty tube detection

Specification

Measurement principle Ultrasonic sensor
Medium Fluids
Output signal Analog output 4 mA … 20 mA, 0 mA … 20 mA current flow and temperature1
pulse/status output PNP/NPN-transistor output for flow rate meter,
empty pipe detection, flow monitoring, dosing output, flow direction
(dependent on type) 1)
Analog output 4 mA … 20 mA, 0 mA … 20 mA current flow and temperature2
pulse/status output PNP/NPN-transistor output for flow rate meter,
empty pipe detection, flow monitoring1 switching input for dosing and counter
reset 1)
Nominal width measuring tube DN 10
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
Maximum adjustable measuring range 0 l/min … 900 l/min
1) All connections are polarity protected. All outputs are overload and short-circuit protected.