The S300 Standard is the cost-effective solution for applications with freely definable protective fields. The new triple field mode allows three fields – one protective field and two warning fields – to be activated at the same time. The compact design means the safety laser scanners can easily be fit to any machine. The S300 Standard is ideally suited to horizontal and vertical protection of hazardous and entrance areas. The configuration memory integrated into the system plug also enables simple commissioning and quick device replacement. CDS (Configuration & Diagnostic Software) can be used to define protective and warning fields in a convenient and standardized way on a PC or laptop.

Features

  • Compact design
  • 2 m or 3 m protective field range
  • 270° scanning angle
  • 1 field set
  • Configuration memory integrated in the system plug
  • EFI interface for safe SICK device communication
  • Measured data output via RS-422
  • Contour as reference for vertical applications

Specification

Application Indoor
Protective field range 2 m / 3 m
Warning field range 8 m
Scanning angle 270°
Number of fields 3
Number of monitoring cases 1
Response time ≤ 80 ms 1)
OSSD pairs 1
Integration in the control system Local inputs and outputs (I/O), EFI
Safety level Type 3, PL d, SIL2
1) Depending on basic response time and multiple sampling.